Product Specifications:

Table

Parameter Item

Standard value

Rated voltage

12 kV (compatible with 3.6 kV/7.2 kV/12 kV systems)

Rated frequency

50Hz/60Hz

Rated busbar current

630A, 1250A, 1600A, 2000A, 2500A, 3150A, 4000A, 5000A

Rated short-circuit breaking current

20/25/31.5/40/50kA

Rated short-time withstand current (4 s)

20/25/31.5/40/50kA

Rated peak withstand current

50/63/80/100/125kA

Lightning impulse withstand voltage (phase-to-phase / phase-to-ground)

75 kV; flashover voltage 85 kV

Power-frequency withstand voltage (1 min)

42kV

Protection rating

Cabinet enclosure IP4X; circuit breaker door open position IP2X

Cabinet external dimensions (width × depth × height)

Standard dimensions: 800×1500×2200 mm; width available in 650/1000 mm.

Cabinet material

Aluminum-zinc coated steel sheet (CNC bending and assembly)

Mechanical life

≥50,000 times

Internal Arc Withstand Capability

Up to 40 kA/1 s, with a standard independent pressure relief channel.

Standard features

Complete Five-Prevention Mechanical Interlock , Operable with the door closed; the shutter automatically isolates energized components.

 

Application scenarios:

  1. Power grid system : Incoming and outgoing lines, metering, for urban substations, switchgear stations, and distribution rooms, PT , Use of busbar sectioning and interconnection cabinets
  2. Industrial and mining enterprises : Factory main distribution room, metallurgy / Chemical industry High-voltage power distribution in coal mines, as well as the starting, stopping, and protection of high-power high-voltage motors.
  3. Building amenities : Commercial complexes, data centers, hospitals, airports, rail transit systems, and large office buildings 10kV Distribution system
  4. New energy sector : Photovoltaic step-up substation, high-voltage switchgear for wind power transformer substations, and primary distribution units for energy storage power stations
  5. Infrastructure : High-voltage power supply and distribution systems for water treatment plants, wastewater treatment plants, industrial parks, and logistics parks

 

Product Advantages:

  1. Fourfold Independently Armored Compartments : The busbar compartment, circuit breaker compartment, cable compartment, and instrument compartment are all fully metal‑enclosed; fault arcs cannot propagate into adjacent compartments, and the pressure‑relief channels direct pressure release, ensuring exceptionally high personal safety. Sigma Electric ...
  2. Reliable Five-Prevention Interlocking System : Forced interlocking prevents load‑carrying disconnector operations, inadvertent circuit breaker opening or closing, energized grounding switch closure, energized closing and power supply, and unauthorized entry into live compartments, thereby meeting State Grid acceptance standards.
  3. Modular handcart design The vacuum circuit breaker’s handcart can be fully withdrawn for maintenance, offering high interchangeability, short fault‑replacement times, and convenient operation and upkeep; its interlocked door automatically seals the stationary contacts when the handcart is inserted or removed, ensuring that no live parts are exposed during maintenance.
  4. Corrosion-resistant and durable cabinet body : Aluzinc steel panels require no painting, offer excellent oxidation resistance and corrosion resistance, and remain rust‑free and deformation‑free even with prolonged indoor use. The cabinet boasts high structural rigidity and an advanced seismic resistance rating. AG5 (Tolerance magnitude earthquake).
  5. High compatibility : Matchable VS1 VD4 Like mainstream vacuum circuit breakers both domestically and internationally, it can be equipped with intelligent modules for temperature monitoring, partial discharge detection, and online comprehensive protection, making it suitable for unmanned distribution substations.
  6. Installation and maintenance-friendly : A double-sided, maintenance‑friendly layout; neatly organized internal wiring; ample cable‑room space; and sufficient workspace for on‑site wiring and maintenance tasks.

Keywords: KYN28-12

Previous page

Next page

If you have further needs, feel free to leave a message—we’ll reply to you as soon as we receive your message!

Send now